Diagnostic Overview for Daikin Error Code L5
Reported Symptoms: Inverter compressor starts for 15-30 seconds then abruptly trips with L5 error on remote control.
Technical Cause: Compressor drive IPM (Intelligent Power Module) short circuit, bridge rectifier breakdown, or current sensing shunt resistor burned.
Step-by-Step Lab Repair Procedure:
Desolder and test IGBT/IPM module with diode test on multimeter. Replace IPM module with genuine STK or Mitsubishi IGBT module, replace 450V electrolytic filter capacitor.