Error Code Fault Meaning & Symptoms Suspected PCB Component Diagnostic Action Lab Repair
U4 Lloyd U4 Error Indoor / Outdoor serial communication failure. Outdoor unit does not start. Communication Optocouplers PC817 & Loop Resistors Oscilloscope test communication pulse waveform; replace faulty optocoupler. WhatsApp Repair Board
L5 Lloyd L5 Error Inverter compressor instantaneous overcurrent trip. IGBT IPM Module & Current Sense Shunt Resistors Check resistance between UVW terminals; desolder blown IPM and test SMPS drive lines. WhatsApp Repair Board
E6 Lloyd E6 Error Outdoor fan motor locked or DC fan feedback missing. DC Fan Motor Driver IC & 15V Gate Supply Line Measure 15V and 310V rails; replace damaged fan driver microcontroller. WhatsApp Repair Board
C4 Lloyd C4 Error Indoor heat exchanger liquid pipe thermistor sensor open or short. Temperature Sensor Bias Network & ADC Input Port Measure thermistor resistance (typically 10k-20k ohm at 25C) and filter capacitor. WhatsApp Repair Board